ISO 8573-1 classes explained: what your air quality class means

ISO 8573-1 grades compressed air for three contaminants: solid particles, water and oil. Each gets a class number, written in that order, so ISO 8573-1:2010 [1:2:1] means particle class 1, water class 2 and oil class 1. The lower the number, the cleaner the air. Class 0 means a limit tighter than class 1, agreed and stated in writing.

How to read an ISO 8573-1 class

ISO 8573-1 is the international standard for compressed air purity. The current edition is the 2010 one, which ISO last confirmed in 2022 and still lists as current on its ISO 8573-1:2010 page. A revised edition is in development. A purity statement always names the edition and gives three numbers in square brackets:

An X in any position means that contaminant is above the highest numbered class, and the maximum figure must then be given in brackets, for example X(15) for 15 g/m³ of liquid water. A dash means it is not specified. Concentrations per cubic metre are stated at reference conditions of 20°C, 1 bar absolute and zero relative water vapour pressure. Pressure dew points apply at the line pressure.

Solid particle classes

Classes 1 to 5 count the maximum number of particles in each cubic metre of air, by size. Classes 6 and 7 use the mass of particles instead.

Class0.1 to 0.5 micron0.5 to 1 micron1 to 5 micron
120,000 or fewer400 or fewer10 or fewer
2400,000 or fewer6,000 or fewer100 or fewer
3Not specified90,000 or fewer1,000 or fewer
4Not specifiedNot specified10,000 or fewer
5Not specifiedNot specified100,000 or fewer
65 mg/m³ or less
7More than 5 and up to 10 mg/m³

Water classes

Classes 1 to 6 set a maximum pressure dew point, which is the temperature at which water vapour in the air would start to condense at line pressure. Classes 7 to 9 cover air that carries liquid water. Our guide to pressure dew point explains why the figure must be measured at line pressure.

ClassPressure dew pointTypical dryer
1minus 70°C or lowerDesiccant (adsorption)
2minus 40°C or lowerDesiccant (adsorption)
3minus 20°C or lowerDesiccant or membrane
4+3°C or lowerRefrigeration
5+7°C or lowerRefrigeration
6+10°C or lowerRefrigeration

Classes 7, 8 and 9 measure liquid water, not dew point: class 7 allows up to 0.5 grams per cubic metre, class 8 more than 0.5 and up to 5 grams, and class 9 more than 5 and up to 10 grams. No production process should be designed around them.

Oil classes

The oil class counts total oil: liquid oil, oil aerosol and oil vapour together. Leaving out the vapour is the most common way a system that looks clean on paper fails a test.

ClassTotal oil content
10.01 mg/m³ or less
20.1 mg/m³ or less
31 mg/m³ or less
45 mg/m³ or less

Coalescing filters remove liquid oil and oil aerosol, but oil vapour passes straight through them. The usual way to reach class 1 from an oil-lubricated compressor is an activated carbon stage after the coalescing filters, and the carbon has a limited life. Confirm the result by testing total oil at the point of use.

What class 0 really means

Class 0 does not mean zero contamination. It means a limit more stringent than class 1, specified in writing by the user or the equipment supplier. A claim of “class 0” with no figure attached tells you nothing.

Class 0 appears most often on oil-free compressors, where the manufacturer states a certified oil content for the air leaving the compressor. That figure covers the compressor alone. Oil vapour already in the air the compressor draws in, and contamination from pipework downstream, can still reach your process, which is why the point of use is where purity should be measured.

Which class do you need?

The process sets the class, and specifying cleaner air than you need costs money in filtration, drying and energy. As a guide:

  • General workshop air and tools: refrigeration-dried and filtered air is usually enough, for example [3:4:3] or similar.
  • Instrument air and spray painting: lower particle and oil classes protect valves and finishes.
  • Food and drink: the British Compressed Air Society (BCAS) Best Practice Guide 102-1 recommends [1:2:1] wherever air comes into direct or indirect contact with food or drink, and [2:4:2] only where there is no contact at all.
  • Pharmaceutical, electronics and breathing air: specific standards or customer specifications apply, often with microbiological limits as well.
  • Air feeding a nitrogen generator: the generator manufacturer specifies the inlet air class. Our article on nitrogen purity for food packaging explains why it matters for food.

Different areas of a site can have different classes. Point-of-use filtration on the one line that needs class 1 oil is usually cheaper than treating all the air to that standard.

How the classes are tested

ISO 8573-1 sets the classes. Other parts of ISO 8573 set the test methods: part 2 for liquid oil and oil aerosol, part 3 for humidity, part 4 for particle count and size, part 5 for oil vapour, part 7 for viable microbiological contamination, part 8 for particle mass and part 9 for liquid water. A test report should say which parts were used and where on the system the samples were taken.

ALS Industrial test compressed air and nitrogen to ISO 8573 on site. See our compressed air quality testing page, or our air quality testing FAQs. If the results show a problem, our dryer servicing team can put it right.

Frequently asked questions

What does ISO 8573-1 class 1.2.1 mean?

It means solid particle class 1, water class 2 and oil class 1. In practice that is very clean air: no more than 20,000 particles of 0.1 to 0.5 micron per cubic metre, a pressure dew point of minus 40°C or lower and no more than 0.01 mg/m³ of total oil.

What is ISO 8573-1 class 0?

Class 0 is a limit stricter than class 1, specified in writing by the user or the equipment supplier. It does not mean zero contamination, so a class 0 claim should always come with the actual figure it refers to.

What compressed air class is needed for food?

The BCAS Best Practice Guide 102-1, Food and Beverage Grade Compressed Air, recommends ISO 8573-1:2010 [1:2:1] for air in direct or indirect contact with food or drink, and [2:4:2] only for air with no food contact at all. Your own risk assessment and customer requirements may set tighter limits.

How is compressed air quality tested?

Samples are taken at the point of use and tested for particles, water and oil using the methods in other parts of ISO 8573, with microbiological testing where it is needed. The report gives a class for each contaminant, which you compare with your specification.