Nitrogen Generator Servicing
PREVENTATIVE
MAINTENANCE
REPAIR
SUPPLY
ALS Industrial Services Ltd service and maintain Parker nitrogen generators across the full NITROSource and SmartFluxx range. Established from Parker Hannifin's Service Centre network in 2016, our engineers have factory-level training on the complete Parker nitrogen generator range, and we are Parker's only UK Warranty Service Agent for compressed air, nitrogen generation and chillers. We also service nitrogen generators from other manufacturers.
The generator produces nitrogen continuously from compressed air using either pressure swing adsorption (PSA) or membrane technology. Both technologies require regular maintenance, and both are sensitive to the quality of the compressed air feeding them.
Typical applications include modified atmosphere packaging (MAP) in food production, blanketing and purging in brewing and beverage, laser cutting assist gas, pharmaceutical manufacturing, electronics assembly and chemical inerting.
Parker NITROSource and SmartFluxx specialists
Parker's NITROSource range uses PSA technology with carbon molecular sieve (CMS) beds, achieving purities from 95% up to 99.999%. The SmartFluxx range uses hollow-fibre membrane technology for point-of-use applications. Our engineers are trained on both technologies and understand the compressed air quality requirements critical to long-term performance.
Common faults we diagnose and resolve:
| Area | Typical faults |
|---|---|
| CMS beds (PSA) | Sieve degradation from oil or moisture contamination, reduced purity, loss of flow capacity |
| Switching valves | Valve cycle failure, solenoid wear, pressure equalisation faults causing purity loss |
| Oxygen analyser | Sensor calibration drift, failed sensor cell, inaccurate purity readings |
| Inlet air quality | Oil carryover from compressor, excess moisture, failed pre-filters, all of which directly shorten CMS bed life |
| Membrane units | Fibre degradation, oil contamination of membrane bundle, reduced purity and flow |
Why nitrogen generator maintenance matters
The carbon molecular sieve beds in a PSA nitrogen generator are sensitive to oil and moisture in the inlet air. A compressor with deteriorating oil separators, or a dryer that is not performing correctly, will shorten CMS bed life significantly. Once contaminated, CMS beds cannot be regenerated on-site and require replacement at considerably greater cost than the preventive maintenance that would have avoided the problem.
Our maintenance visits cover the generator and the upstream compressed air system that feeds it:
- Nitrogen purity verification and oxygen analyser calibration check
- Valve cycle test and switching valve condition assessment
- Inlet air quality check: oil content, pressure dew point, particulates
- Pre-filter inspection and element condition assessment
- Flow and pressure performance test against specification
- Control system and alarm check
- Written service record issued on completion
Customers on a service contract also benefit from priority cover for breakdowns.
How can we help?
Our engineers have worked on Parker nitrogen generators across a wide range of industries and installations. Whether your generator is not reaching specified purity, a switching valve needs replacing or your system has never been properly commissioned for the inlet air quality it requires, we can assess it and advise on the best way forward.